Bently Nevada 3500/50 133388-02 Module Brand New
Description
Extensive alarm and event lists retain the
2000 most recent alarm events and 1000
most recent system events (configuration
changes, errors, etc.). The system’s TDI
retains the lists, which provide a
description of each alarm or event and a
corresponding date/time stamp. These
lists are available to the 3500/94M VGA
Display module and also to the
Communication Gateway module for
export to process control, historian, or
other plant systemsNetworked connections allow you to
remotely configure a 3500 system and
even assess the system when an
instrument problem arises. You can
implement simple changes, such as to an
alarm setpoint or a filter corner, without
traveling to the site in person. This is
useful for installations at offshore
platforms, compressor or pump stations,
emergency generators, and other
locations where on-site access to the
instrumentation is inconvenient or
impractical.
Cybersecurity
The 3500 System’s two levels of password
protection combined with a keylock for
configuration changes ensures the system
can’t be adjusted, changed, or configured
except by authorized personnel.
The 3500 rack records any configuration
changes in the system’s event list, which
accommodates effective “management of
change” documentation.
We also offer Wurldtech™ Achilles® Level
1 certified solutions as well as full
engineered and hardened network
architectures when required to meet
specific cybersecurity needs.
Bentley Nevada 3500 Series Modules
Bently Nevada 3500/05, 3500/06,3500/08,3500/15,3500/20,3500/22M ,3500/25,3500/32,3500/33,3500/34,3500/40M,3500/42,3500/65 184469-01, 3500/44M, 3500/45, 3500/46, 3500/50, 3500/53, 3500/60, 3500/61, 3500/62, 3500/64M, 3500/65, 3500/70M, 3500/60, 3500/65,3500/72M,3500/77M, 3500/90, 3500/33, 3500/33 149992-01, 3500/33 149986-01, 3500/53, 3500/53 133388-01, 3500/53 133396-01, 3500/65 184522-01, 3500/92, 3500/92 136180-01, 3500/92(136180-01), 3500/15 125840-01, 3500/15 133300-01, 3500/15 127610-01
Ordering Information
The 3500/33 requires 3500 Rack Configuration software, version 3.3 or later
The 3500/33 requires 3500 Data Acquisition software, version 2.40 or later
The 3500/33 requires 3500 Data Display software, version 1.40 or later
When used with a 3500/93 LCD Display module, the 3500/93 will require firmware revision P or later.
When used with a 3500/94 VGA Display module, the 3500/94 will require firmware revision C or later
You May Be Wnat To Buy
DSQC643 | 51401496-100 | IC3000CS200M |
DSQC651 3HEA800439-002 | 51401291-100 | IC200UDR005-AA |
DSQC652 | 51401288-200 | IC200PWR102E |
DSQC652 3HAC025917-001 | 51401286-100 | IC200PWR102 |
DSQC652 3HAC025917-001/00 | 51401052-100 | IC200PWR101E |
DSQC658 | 51400910-100 | IC200PWR101 |
DSQC661 3HAC026253-001 | 51400855-100 | IC200PWR002 |
DSQC662 3HAC026254-001/11 | 51400646-100 | IC200PWR001 |
DSQC663 3HAC029818-001 | 51309512-175 | IC200PWB001D |
DSQC668 3HAC029157-001 | 51309288-375 | IC200PNS002 |
DSQC679 3HAC028357-001 | 51309288-275 | IC200PNS001 |
DSQC697 | 51309288-225 | IC200PBI001 |
DSQC697 3HAC037084-001 | 51309288-125 | IC200MDL940 |
DSRF182 | 51309283-600 | IC200MDL930 |